{"id":407,"date":"2017-08-24T12:57:42","date_gmt":"2017-08-24T10:57:42","guid":{"rendered":"http:\/\/wp.doc-labor.de\/?page_id=407"},"modified":"2018-07-24T13:49:41","modified_gmt":"2018-07-24T11:49:41","slug":"reqirements","status":"publish","type":"page","link":"https:\/\/doc-labor.de\/?page_id=407","title":{"rendered":"Reqirements"},"content":{"rendered":"<p>These are some basic requirements for the installation of an LC-OCD-OND system.<\/p>\n<p>if you need further information, please do not hesitate, to contact us.<\/p>\n<hr \/>\n\n<ul class=\"nav nav-tabs sc_tabs kt-tabs kt-sc-tabs kt-tabs-style1\"><li class=\"active\"><a href=\"#sctab82940\"><\/p>\n<h4>Laboratory<\/h4>\n<p><\/a><\/li>\n<li class=\"\"><a href=\"#sctab82941\"><\/p>\n<h4>System maintenance<\/h4>\n<p><\/a><\/li>\n<li class=\"\"><a href=\"#sctab82942\"><\/p>\n<h4>Miscellaneous<\/h4>\n<p><\/a><\/li><\/ul> <div class=\"tab-content kt-tab-content postclass\"><div class=\"tab-pane clearfix active\" id=\"sctab82940\">\n<p><strong>Space<\/strong><\/p>\n<p>Floor system, not bench system. Minimal floor space required: 90 cm x 70 cm (W\/D).<\/p>\n<hr \/>\n<p><strong>Climatisation<\/strong><\/p>\n<p>Laboratory conditions preferred, non-laboratory conditions possible.<\/p>\n<p>Room should be climatized to any temperature between 18 &#8211; 27 \u00b0C \u00b1 2\u00b0C.<br \/>\nShort temperature changes in excess of \u00b1 2\u00b0C may induce slight baseline drifts.<\/p>\n<p>Do not expose LC-OCD-OND to direct sunlight.<\/p>\n<hr \/>\n<p><strong>Laboratory environment<\/strong><\/p>\n<p>Please try to make the lab where LC-OCD-OND is positioned to a TOC-sensitive area.<\/p>\n<p>This includes the following:<\/p>\n<ul>\n<li>No organic solvents must be used in the lab. If HPLC-systems with organic solvents are present then special precautions (e.g. hoods or carbon filters for HPLC mobile phase flasks) should be taken.<\/li>\n<li>No felt pens are allowed in the lab.<\/li>\n<li>No perfumes, no creams, no hair conditioner for personal working in the lab.<\/li>\n<\/ul>\n<p>Please note: Volatile organics do not impair the performance of the LC-OCD system, but organics may contaminate samples.<\/p>\n<\/div>\n<div class=\"tab-pane clearfix \" id=\"sctab82941\">\n<p><strong>Gases<\/strong><\/p>\n<p>For operation nitrogen 4.0 or better is required. Supply either on-site (pressure bottle) or central.<\/p>\n<p>Nitrogen consumption beween 180-240 sccm\/min. (50L-bottle lasts for about 4 weeks continuous operation).<\/p>\n<p>Nitrogen must be reduced to 0.5-1.0 bar. Pressure reducer must have a Swagelok 1\/8&#8243; outlet. Teflon or SS tubing to LC-OCD-OND can be pre-mounted or will be carried out by us.<\/p>\n<p>Note: Conventional Nitrogen Generators with PSA often do not supply the quality required, due to fluctuations in CO2 content!<br \/>\nFor such systems additional purification steps may be necessary. In case of uncertainty we recommend to provide a 10L-bottle for testing.<\/p>\n<hr \/>\n<p><strong>Electricity<\/strong><\/p>\n<p><em>Model 9 (2018+):<\/em><br \/>\n100 &#8211; 240 V, 50\/60 Hz are possible. Consumption is about 450 W\/hr. One socket only is required for LC-OCD-OND.<br \/>\nMaximal distance of sockets to LC-OCD-OND is 5 m. Customer is kindly asked to provide at least two local plugs in case plugs have to be changed.<\/p>\n<p><em>Model 8 (2008-2017):<\/em><br \/>\n220 &#8211; 240 V, 50 Hz are required. Consumption is about 400 W\/hr. At least 3 sockets are required, one for LC-OCD-OND, one for Laptop and one for waste water pump.<br \/>\nMaximal distance of sockets to LC-OCD-OND is 5 m. Customer is kindly asked to provide at least two local plugs in case plugs have to be changed.<\/p>\n<hr \/>\n<p><strong>Waste<\/strong><\/p>\n<p>Waste produced is mild phosphate buffer pH 5, about 5 g\/L. Waste is exported with external pump either to a nearby container, or better with a tubing to a sink.<\/p>\n<p>We kindly ask customer to provide silicon or PP tubing for connection of waste pump to sink.<\/p>\n<hr \/>\n<p><strong>Chemicals<\/strong><\/p>\n<p>We kindly ask customers to have the following chemicals on stock prior to installation of system.<br \/>\nSystems will be shipped with smaller amounts of chemicals for about 1-month operation<\/p>\n<p><em>Mobile Phase<\/em><\/p>\n<ul>\n<li>Potassium-dihydrogenphosphate<br \/>\nCAS 7778-77-0, e.g. Sigma Aldrich P0662-1KG or Merck 1.04873.1000<\/li>\n<li>Disodium-hydrogenphosphate-dihydrate<br \/>\nCAS 10028-24-7, e.g. Sigma Aldrich 30435-1KG or Merck 1.06580.1000<\/li>\n<\/ul>\n<p><em>Acidification solution<\/em><\/p>\n<ul>\n<li>Orthophoshoric Acid 85 %<br \/>\nCAS 7664-38-2, e.g. Sigma Aldrich 695017-2.5L or Merck 1.00573.2500<\/li>\n<li>Potassium Peroxodisulfate<br \/>\nCAS 7727-21-1, e.g. Sigma Aldrich 60489-1KG or Merck 1.05091.1000<\/li>\n<\/ul>\n<p><em>Calibration of Detectors<\/em><\/p>\n<ul>\n<li>Potassium Hydrogen Phthalate<br \/>\nCAS 877-24-7, e.g. Sigma Aldrich 60359-250G or Merck 1.04874.0250<\/li>\n<li>Potassium Nitrate<br \/>\nCAS 7757-79-1, e.g. Sigma Aldrich 31263-100G or Merck 1.05063.0500<\/li>\n<\/ul>\n<p><em>Calibration of Molecular masses<\/em><\/p>\n<ul>\n<li>Suwannee River Humic Acids Standard II, Catalog # 2S101 H<\/li>\n<li>Suwannee River Fulvic Acids Standard II, Catalog # 2S101 F<br \/>\nOrder from https:\/\/ihss.humicsubstances.org<br \/>\n(Small amounts of Humic Substances will be shipped with LC-OCD systems.)<\/li>\n<\/ul>\n<\/div>\n<div class=\"tab-pane clearfix \" id=\"sctab82942\">\n<p><strong>Glassware<\/strong><\/p>\n<p>Please have the following materials on stock:<\/p>\n<ul>\n<li>1 x 5L volumetric flask<\/li>\n<li>1 x 5L Schott-flask amber (for mobile phase)<\/li>\n<li>1 x 5L Schott flask transparent (for acidification solution)<\/li>\n<\/ul>\n<p>For cleaning of vials:<br \/>\nWe recommend 3 basins about 10 L each for chemical cleaning.<br \/>\nAlternative: A kiln or oven for heating up vials to 550 \u00b0C.<\/p>\n<p>Also standard laboratory equipment for dilution and weighting-in is required.<\/p>\n<hr \/>\n<p><strong>Staff<\/strong><\/p>\n<p>We recommend to have at least 2 persons being instructed.<\/p>\n<p>We suggest to have one person identified as main responsible person or principal operator.<br \/>\nThis person has to make sure that system is running well and also has to organise and train supporting personal in case of absence.<br \/>\n<\/div><\/div>\n\n<p><!--Buttons--><\/p>\n<div class=\"tcol-lg-3 tcol-md-3 tcol-sm-3 tcol-xs-3 tcol-ss-12 home-iconmenu homeitemcount4\"><a title=\"Contact us\" href=\"http:\/\/doc-labor.de\/?page_id=38\" target=\"_self\"><br \/>\n<i class=\"icon-envelope-alt\"><\/i><\/p>\n<h4>Contact us<\/h4>\n<p><\/a>\n<\/div>\n<div class=\"tcol-lg-3 tcol-md-3 tcol-sm-3 tcol-xs-3 tcol-ss-12 home-iconmenu homeitemcount4\"><a title=\"Specifications\" href=\"http:\/\/doc-labor.de\/?page_id=422\" target=\"_self\"><br \/>\n<i class=\"icon-book\"><\/i><\/p>\n<h4>Specifications<\/h4>\n<p><\/a>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>These are some basic requirements for the installation of an LC-OCD-OND system. if you need further information, please do not hesitate, to contact us. Contact us Specifications &nbsp;<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":354,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"page-fullwidth.php","meta":{"footnotes":""},"class_list":["post-407","page","type-page","status-publish","hentry"],"jetpack_shortlink":"https:\/\/wp.me\/P9uTgp-6z","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/doc-labor.de\/index.php?rest_route=\/wp\/v2\/pages\/407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/doc-labor.de\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/doc-labor.de\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/doc-labor.de\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/doc-labor.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=407"}],"version-history":[{"count":17,"href":"https:\/\/doc-labor.de\/index.php?rest_route=\/wp\/v2\/pages\/407\/revisions"}],"predecessor-version":[{"id":671,"href":"https:\/\/doc-labor.de\/index.php?rest_route=\/wp\/v2\/pages\/407\/revisions\/671"}],"up":[{"embeddable":true,"href":"https:\/\/doc-labor.de\/index.php?rest_route=\/wp\/v2\/pages\/354"}],"wp:attachment":[{"href":"https:\/\/doc-labor.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}